NXA Phase Noise Analyzer

The All-In-One Phase Noise Test System

The NXA is a fully automated Phase Noise analyzer. Its dual channel architecture allows the system to use a cross-correlation process to cancel its internal noise floor. This reliable technique provides access to the unique noise floor performance of the DCNTS.

A completely new user interface based on the largest 14 inch touchscreen of the industry that simplifies the operation, focusing the user on the measurement result itself and not on the measurement technique. Experts can always access advanced settings if needed.

Quick and easy phase noise plots can be obtained without any training so any manufacturing technician can operate the NXA Series. This is the only instrument that combines great ease of use and state of the art performance.

With its internal frequency references, measurements are made extremely easy without the hassle of connecting cables and tweaking settings. However, when ultimate performance is required, the capability to use external reference sources like crystal oscillators, SAWs or SLCOs pushes the instrument noise floor down to the thermal noise.

NXA-6_small

Why the NXA Series ?

  • RF and Microwave Devices from 2 MHz to 6, 26 or 50 GHz
  • Cross-Correlation technique
  • Reference sources built-in for residual and absolute phase noise testing
  • Single button fast measurement
  • Residual/Additive Phase Noise Measurements capable
  • Frequency Stability (Allan Variance and Deviation) up to 10,000 seconds
  • CW or pulsed signals compatible (CW only for NXA-6)
  • Ideal for the manufacturing floor.
  • NIST tested Calibration accuracy

Specifications

NXA-6 Specifications

SPECIFICATION VALUE
Input Frequency : 2 MHz to 6.2 GHz
Offset analysis 0.001 Hz to 40 MHz
Cross Correlation averages 1 to 100,000, individually settable per offset decade
Accuracy 1 Hz- 1 MHz offset: +/- 2 dB
Accuracy 1 M – 40 MHz offset: +/- 3 dB

For more specification please download our shortform datasheet or request our complete NXA datasheet that includes many test examples.

NXA-26 Specifications

Input Frequency : 2 MHz to 26.5 GHz
Offset analysis 0.001 Hz to 40 MHz
Cross Correlation averages
1 to 100,000, individually settable per offset decade
Accuracy 1 Hz – 1 MHz offset: +/- 2 dB
Accuracy 1 M – 40 MHz offset: +/- 3 dB

For more specification please download our shortform datasheet or request our complete NXA datasheet that includes many test examples.

NXA-50 Specifications

Input Frequency : 2 MHz to 50 GHz
Offset analysis 0.001 Hz to 40 MHz
Cross Correlation averages 1 to 100,000, individually settable per offset decade
Accuracy 1 Hz – 1 MHz offset: +/- 2 dB
Accuracy 1 M – 40 MHz offset: +/- 3 dB

For more specification please download our shortform datasheet or request our complete NXA datasheet that includes many test examples.

Main Options list

  • Amplitude Noise detector allows Amplitude noise measurements.
  • Pulsed signals compatibility to measure gated CW type signals.

Many other options available as standard. We also offer custom modules to suit your application.

File Description File Name
NXA-6 Short Form Datasheet – PDF – 374 Ko Noise XT NXA 6.pdf
NXA-26 Short Form Datasheet – PDF – 313 Ko Noise XT NXA 26.pdf
NXA-50 Short Form Datasheet – PDF 289 Ko Noise XT NXA 50.pdf

Noise_XT_NXA_3_configurationsPhase Noise_XT_NXA_6